A glass meeting room can bring natural light into an office while giving teams a dedicated place for calls, discussions and client meetings. When those conversations involve sensitive information, the design brief becomes more specific: people need a room that supports privacy as well as a connected workplace.
The partition is central to that discussion. Its glass, framing and construction influence how sound travels between the meeting room and the surrounding office. The door, ceiling and building services also need to be considered as part of the completed space.
Sound Transmission Class, commonly known as STC, gives businesses and design teams a way to compare the sound insulation of tested partitions and doors. Understanding what the rating covers makes it easier to review product specifications and choose a system that suits the intended use of the room.
STC is a single-number rating used to describe the sound insulation of a tested building element against airborne sound. It can be applied to elements such as partitions, doors and floor-ceiling assemblies.
A higher STC rating generally indicates that the tested construction provides greater sound insulation. When comparing two office partition systems, the rating gives the design team a starting point for discussing their performance alongside appearance, space requirements and budget.
The rating applies to the specific construction that was tested. A product sheet should therefore be read together with the details of the assembly, including its glass, framing and other components.
In a laboratory, sound transmission loss can be measured using ASTM E90. The resulting data can then be classified using ASTM E413. USG’s guide to acoustic principles explains STC as a way to compare the sound attenuation of tested partitions.
An STC rating summarises performance across a range of sound frequencies. It is useful for comparison, but it does not mean that every sound will be reduced by the same number of decibels.
A meeting room’s privacy also depends on more than the partition’s laboratory rating. The door, ceiling connections, surrounding construction and background sound outside the room all contribute to how easily a conversation can be heard or understood.
For a Hong Kong office fit-out, the most useful approach is to connect the STC discussion to the room’s purpose. A room used for informal team catch-ups may have different requirements from one used for employee interviews, financial discussions or confidential client meetings.
The appropriate specification starts with how the room will be used and what is happening around it. A meeting room beside a busy pantry may face different acoustic conditions from an HR room next to a quiet workstation area.
The brief should consider the type of conversation, how often the room is used, who occupies the neighbouring space and the level of discretion the business expects. These details help the design team assess the partition, door and room construction together.
| Room or activity | Main acoustic consideration | Question for the project team |
|---|---|---|
| Internal team meeting room | Reduce disruption to nearby staff | What is next to the room, and how frequently will it be used? |
| Client meeting room | Support a comfortable, professional discussion | How much separation is needed from circulation and work areas? |
| HR or management room | Support privacy for sensitive conversations | What level of speech privacy should guide the room specification? |
| Video conferencing room | Support privacy and clear audio | How will sound insulation, room finishes and AV equipment work together? |
| Flexible training room | Support different group activities | Does the space need an operable partition, and how will it be used? |
Published guidance can help establish a starting point. The US General Services Administration’s Sound Matters workplace acoustics guide discusses partition performance for different levels of speech privacy and describes the role of doors and seals in enclosed rooms.
The guide reflects a US workplace context and provides a reference for discussion. The final specification should be developed around the project’s floor plan, construction, building requirements and privacy objectives.

JEB X-Series partition visual. Source: JEB Group.
Glass partitions are available in several configurations, including single glazing, laminated glass and double glazing. Their acoustic performance depends on the tested construction, so a useful comparison includes the glass specification and the partition system as a whole.
JEB’s X-Series technical data provides an example of how the reported STC changes across four configurations:
| JEB X-Series partition configuration | Reported STC |
|---|---|
| Single glazed: 12 mm tempered glass | 36 |
| Single glazed: 13.52 mm laminated glass | 38 |
| Double glazed: 10 mm + 12 mm tempered glass | 45 |
| Double glazed: 11.52 mm + 13.52 mm laminated glass | 49 |
Source: JEB Group, X-Series technical data, July 2026. Ratings apply to the listed configurations.

Source: JEB Group, X-Series technical data, July 2026.
These examples give the design team a basis for comparing options. A business that values transparency can discuss the available glazing configurations alongside its meeting-room privacy requirements, the surrounding office layout and the overall project budget.
The product sheet should also be reviewed for the frame, glazing composition and other details associated with the test. When a project requires a particular level of performance, the supplier can provide the relevant test documentation for the proposed system.
A single-glazed partition uses one glazed layer within the system. It can provide a visually open meeting space and may suit rooms where the privacy requirement matches the performance of the selected configuration.
Laminated glass combines glass layers with an interlayer. Different products and interlayers have different properties, so the specification should identify the glass used in the tested partition rather than rely on the word “laminated” alone.
Double-glazed systems use two glazed layers separated by a cavity. They provide another option for projects that need a higher level of acoustic separation while retaining a glazed appearance. The glass composition, cavity, frame and connections should be considered together when reviewing the system.
The door is part of the meeting room’s acoustic design. It allows people to enter and leave the room throughout the day, so its construction, frame, seals, hardware and operation all need to support the intended use of the space.
A project team may compare a partition and a compatible door that have different reported STC ratings. Reviewing both specifications helps the business understand what is being proposed and where further coordination is needed.
JEB’s door brochures show several examples:
| JEB door configuration | Reported STC |
|---|---|
| Studio Door: single-glazed, 12 mm tempered glass | 32 |
| Plus Lite Door: double-glazed, 6 mm + 8 mm tempered glass | 39 |
| Plus Lite Door: double-glazed, 6 mm tempered + 9.52 mm laminated tempered glass | 41 |
| Studio Door: double-glazed, 11.52 mm + 13.52 mm laminated tempered glass | 45 |
Source: JEB Group, Studio Door technical data, July 2026, and Plus Lite Door technical data, August 2026. Ratings apply to the listed door configurations.
The Studio Door specification also describes perimeter acoustic seals and an automatic bottom drop seal. These details are useful when discussing how a door is intended to perform and what needs to be included in the proposed installation.

JEB Obsidian system visual. Source: JEB Group.
JEB’s Obsidian technical data illustrates why the description beside a rating matters. The brochure lists STC 50 for a specified double-glazed partition configuration and STC 45 for a specified sliding-door-and-sidelight configuration.
Both figures are useful, and each describes a different tested arrangement. When reviewing a quotation, the business can ask the supplier which figure applies to the proposed partition, which applies to the door, and how the selected components will be coordinated in the room.

Source: JEB Group, Obsidian technical data, August 2026. Ratings apply to the listed configurations.

Above-ceiling construction brings together partition details, the building structure and services.
The finished office ceiling conceals a space that often contains air-conditioning ducts, electrical routes, pipework and structural elements. For an enclosed room, the design team needs to coordinate these services with the partition and its connections.
A partition may meet a suspended ceiling, extend above it or connect to the structure above, depending on the design and project requirements. The intended acoustic separation should be considered when these details are developed, particularly where the ceiling void connects neighbouring spaces.
The relationship between the partition, ceiling and structural slab influences how the room is constructed. During planning, the team can review the available ceiling space, existing building conditions and the route of services before finalising the details.
This coordination is especially relevant in an occupied or complex office floor, where existing ducts and electrical installations may influence the path of a new partition. Early review gives the project team a clearer basis for preparing drawings, sequencing the work and discussing the proposal with building management.

Above-ceiling partition details are coordinated with pipework and other building services.
Building services need to reach the spaces they support. Air-conditioning, power, data and fire services are therefore considered alongside the room’s acoustic design.
Where services pass through a partition or run above a ceiling, the design and construction teams can review the relevant openings and junctions. The aim is to develop details that accommodate the services and support the acoustic requirements of the room.
A huddle room at Surbana Jurong’s Hong Kong office, designed and built by MJPM.
STC and NRC both appear in acoustic product discussions, but they describe different properties. STC is used to compare sound transmission through a tested element, such as a partition or door. NRC, or Noise Reduction Coefficient, is used to compare sound absorption by a material. USG’s guide to acoustic principles explains these as separate measures.
| Measure | What it helps describe | Office application |
|---|---|---|
| STC | Sound transmission through a tested building element | Comparing meeting-room partitions and doors |
| NRC | Sound absorption by a material | Comparing finishes used to control reflections inside a room |
A meeting room may need both considerations. The partition and door contribute to separation from the surrounding office, while suitable interior finishes can help manage reflections inside the room. For a video meeting, that internal acoustic environment also affects how clearly participants hear one another.
MJPM’s office acoustic design guide explores these wider workplace considerations, including meeting-room sound, open-plan noise and acoustic zoning.
The most effective comparison starts with a clear brief. Once the business and design team understand how the room will be used, they can assess suitable products and coordinate the construction around them.
List the main activities expected in each enclosed room. A workplace may need spaces for short calls, client presentations, team meetings and sensitive discussions, with different priorities for each.
Consider the neighbouring areas as well. A room beside a quiet finance team, reception area or busy collaboration space may need a different design response. The goal is to understand the relationship between the room and the rest of the floor.
Ask for the specification of the proposed partition and door, including glass composition, frame, seals and hardware. Review the STC figures with the descriptions of the tested assemblies.
Where a particular acoustic outcome is important to the project, the team can request the underlying test report and check the tested configuration against the proposed design. This helps everyone discuss the same product and the same scope of performance.
The room’s layout should be reviewed alongside the floor plate, ceiling, structure and building services. Columns, air-conditioning routes and existing electrical installations can all influence where a partition is placed and how it is constructed.
The project team should also identify the relevant building-management and landlord requirements early. This gives the designers and contractors time to coordinate their proposals with the wider fit-out programme.
The specification becomes most useful when it is carried through the drawings, procurement and installation process. Clear responsibilities help the partition supplier, fit-out contractor and building-services teams coordinate the details that affect the finished room.
For spaces with a higher privacy requirement, the business can discuss whether field testing is appropriate and agree the method and acceptance criteria with the relevant specialists. That decision should be made early enough to form part of the project brief.
Before approving an acoustic partition, a business can use these questions to guide the discussion:
These questions help turn an acoustic requirement into a clearer design brief. They also give the business a practical basis for comparing proposals and understanding the decisions that affect the finished workplace.
An effective meeting room brings together several decisions: where it sits on the office floor, how people use it, which partition and door are selected, and how the surrounding construction is coordinated. STC ratings support those decisions by giving the project team a way to compare tested products.
The right approach depends on the conversations taking place and the workplace around them. A business planning an open, collaborative office can retain visual connection while providing enclosed rooms for activities that need greater privacy. MJPM’s guide to open-office design and collaboration looks at how these spaces can be arranged across the floor.
If you are planning a meeting-room upgrade, office renovation or relocation in Hong Kong, contact MJPM to discuss your floor plan, privacy requirements and partition options. The conversation can begin with how your team uses the space and develop into a coordinated design for the finished office.